Signal Too High. Permanent Fault
Signal too high. Permanent fault
Checking wiring and components
Check EVAP canister shut-off valve resistance.
Check signal cable between control module #B40 (#B50) and EVAP canister shut-off valve terminal 2 for a short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
Hint: Use an electrician's screwdriver with at least a 3 W bulb to determine whether the cable is short-circuited to supply voltage.
Remedy as necessary.
Other information
- Connecting the breakout box/accessing the control module, see Connecting the breakout box, B5234T9, B5244T7 Connecting The Breakout Box.
- To access/replace the EVAP canister shut-off valve see.
- For resistance values, see Component specifications Specifications.
- For information about signals, see Signal specification Signal Specifications.
Continue - Verification
-------------------------------------------------
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off.
- Reconnect connectors, reinstall components.
- Ignition on.
- Activate EVAP canister shut-off valve.
A "click" should be heard when the EVAP canister shut-off valve is activated.
Is the EVAP canister shut-off valve working?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFICATION FAILED - Fault-tracing information
VERIFIED - FAULT FOUND
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - Exit fault-tracing
No - Attempt New Test
------------------------
Attempt New Test - Checking wiring and components
-------------------------------------------------