Signal Too High - Intermittent Fault
Signal too high. Intermittent fault
Checking the wiring
Caution! Do not apply rust solvent spray or grease to the heated oxygen sensor (HO2S) connector.
Check the signal cable (+) between heated oxygen sensor (HO2S) terminal #4 and control module terminal #A61 (#B1). Check the signal cable (-) between heated oxygen sensor (HO2S) terminal #3 and control module terminal #A62 (#B2). Check for an intermittent short-circuit to supply voltage.
Other information:
- To connect the breakout box / access the control module, see Connecting the breakout box, B5244T5, B5254T2 Connecting the Breakout Box
- To access or replace the heated oxygen sensor (HO2S), see Heated oxygen sensor (HO2S), replacing Heated Oxygen Sensor (HO2S), Replacing
- For information about signals on 5 cylinder engines, see Signal specification Signal Description / Specification
- For information about signals on 6 cylinder engines, see Signal specification Signal Description / Specification
- Checking wiring and terminals Checking Wiring And Terminals.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - Fault Found
------------------------
Attempt New Test - Checking the wiring
FAULT FOUND - DONE
-------------------------------------------------