Signal Too Low. Intermittent Fault
Signal too low. Intermittent fault
Checking the wiring
Check the cable between injector terminal 2 and control module:
- terminal #A16 (ECM 2310)
- terminal #A15 (ECM 2320)
- terminal #A33 (ECM 2330)
- terminal #A32 (ECM 2340)
- terminal #A34 (ECM 2350)
- terminal #A14 (ECM 2360).
Check for an intermittent short-circuit to ground.
Other information
- To connect the breakout box / access the control module, see Connecting the breakout box, B5254T2 Connecting the Test Box
- To access or replace the injector, see Injectors/pulsation dampers, replacing Service and Repair
- For information about signals, see Signal specification Signal Specification
- Checking wiring and terminals Checking Wiring And Terminals.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - Exit fault-tracing
------------------------
Attempt New Test - Checking the wiring
-------------------------------------------------