Faulty Signal. Intermittent Fault
Faulty signal. Intermittent fault
Checking the wiring
Caution! Do not apply rust solvent spray or grease to the heated oxygen sensor (HO2S) connector.
Check the signal cable (+) between heated oxygen sensor (HO2S) terminal #4 and control module terminal #A10 (#A10). Check the signal cable (-) between heated oxygen sensor (HO2S) terminal #3 and control module #A11 (#A11). Check for an intermittent short-circuit to ground.
Other information:
- To connect the breakout box and access the control module, see Connecting the breakout box, B5254T2 Connecting the Test Box
- To access or replace the heated oxygen sensor (HO2S), see Heated oxygen sensor (HO2S), replacing Heated Oxygen Sensor (HO2S), Replacing
- For information about signals, see Signal specification Signal Specification
- Checking wiring and terminals Checking Wiring And Terminals.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - Exit fault-tracing
------------------------
Attempt New Test - Checking the wiring
-------------------------------------------------