Operation CHARM: Car repair manuals for everyone.

Signal Too Low. Intermittent Fault






Signal too low. Intermittent fault

Checking the wiring
Check the signal cable between control module terminal #A9 (#A9) and evaporative emission system (EVAP) valve terminal 2. Check for an intermittent short-circuit to ground.

Other information:
- To connect the breakout box / access the control module, see Connecting the breakout box, B5254T2 Connecting the Test Box
- For the location of components on 5 cylinder engines, see Location of components Locations
- For the location of components on 6 cylinder normally aspirated engines, see Location of components Locations
- For the location of components on 6 cylinder turbocharged engines, see Location of components Locations
- For information about signals on 5 cylinder engines, see Signal specification Signal Specification
- For information about signals on 6 cylinder engines, see Signal specification Signal Specification
- Checking wiring and terminals Checking Wiring And Terminals.













Continue - Fault-tracing information

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).

Do you want to view the information again?

Yes - Attempt New Test

No - Exit fault-tracing

------------------------

Attempt New Test - Checking the wiring

-------------------------------------------------