LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2006 >> XC90 AWD L5-2.5L Turbo VIN 59 B5254T2 >> Repair and Diagnosis >> Powertrain Management >> Computers and Control Systems >> Diagrams >> Diagnostic Aids >> Checking Wiring and Terminals >> Checking Wiring and Terminals - Permanent Faults >> Short-Circuit to Ground, Permanent Faults

Short-Circuit to Ground, Permanent Faults




Short-circuit to ground, permanent faults







A short-circuit between a live cable and ground is often indicated by the loss of a function or a fuse blowing when a current is passed through the cable.

Repair wiring and cable terminals, using appropriate procedures.

Checks:
- Check terminals visually.
- Activate all switches and sensors in the circuit. Check whether the fuse blows
- Disconnect the connectors in the circuit to ensure that they do not affect readings.

Use an ohmmeter to take a resistance reading between the cable and ground.
The ohmmeter should read infinite resistance if no components are connected.

Check pins and terminals particularly for this fault. See "Check Terminals Visually."