DTC C
DTC indicator C: An open in the outside air temperature sensor circuit1. Remove the outside air temperature sensor and test it.
Does the outside air temperature sensor test OK?
YES - Go to step 2.
NO - Replace the outside air temperature sensor.
2. Disconnect climate control unit connector B (26P).
3. Check for continuity between the No.18 terminal of climate control unit connector B (26P) and the No.1 terminal of the outside air temperature sensor 2P connector
Is there continuity?
YES - Go to step 4.
NO - Repair open in the wire between the climate control unit and the outside air temperature sensor.
4. Check for continuity between the No.1 terminal of climate control unit connector B (26P) and the No.2 terminal of the outside air temperature sensor 2P connector.
Is there continuity?
YES - Check for loose wires or poor connections at climate control unit connector B (26P) and at the outside air temperature sensor 2P connector. If the connections are good, substitute a known-good climate control unit, and recheck. If the symptom/indication goes away, replace the original climate control unit.