B1232
DTC Troubleshooting: B1232 (H)
DTC B1232 or DTC indicator H :
A Short in the Evaporator Temperature Sensor Circuit
NOTE:If DTC B1232 is detected with HDS, it is not necessary to do step 1.
1. Check the sensor input display mode, and select "evaporator temperature" according to the table Initial Inspection and Diagnostic Overview.
NOTE: This indication by segment lit on digital segments is assigned for 2 failure causes that it is necessary to decide which one is a true cause. If there is a failure in the sensor or motor, a value corresponded to the sensor or motor in the Sensor Input Display Mode is displayed as "Er", which serves to specify which is a true cause.
Is sensor value indicated "Er"?
YES -
Go to step 2
NO -
Go to troubleshooting DTC B1205 or DTC indicator H B1205
2. Clear the DTC with the HDS.
3. Turn the ignition switch to LOCK (0), and then back to ON (II).
4. Do the self-diagnostic with the HDS Initial Inspection and Diagnostic Overview or the climate control unit Initial Inspection and Diagnostic Overview.
5. Check for DTCs.
Is DTC B1232 or H indicated?
YES -
Go to step 6.
NO -
Intermittent failure. Check for loose wires or poor connections on the evaporator temperature sensor circuit.�
6. Turn the ignition switch to LOCK (0).
7. Test the evaporator temperature sensor Evaporator Temperature Sensor Test.
Is the evaporator temperature sensor OK?
YES -
Go to step 8.
NO -
Replace the evaporator temperature sensor Service and Repair.�
8. Disconnect climate control unit connector A (24P).
9. Check for continuity between body ground and climate control unit connector A (24P) terminal No. 13.
Is there continuity?
YES -
Repair a short to body ground in the wire between the climate control unit and the evaporator temperature sensor.�
NO -
Go to step 10.
10. Check for continuity between climate control unit connector A (24P) terminals No. 13 and No. 18.
Is there continuity?
YES -
Repair a short in the wires between the climate control unit and the evaporator temperature sensor.�
NO -
Substitute a known-good climate control unit, and recheck. If the symptom/indication goes away, replace the original climate control unit Climate Control Unit Removal/Installation.�