Rear Vent Control Motor Test
Rear Vent Control Motor Test
NOTE: Before testing, check for climate control DTCs Initial Inspection and Diagnostic Overview.
1. Disconnect the 5P connector from the rear vent control motor.
NOTICE
Incorrectly applying power and ground to the rear vent control motor will damage it. Follow the instructions carefully.
2. Connect battery power to terminal No. 1 of the rear vent control motor, and ground terminal No. 2; the rear vent control motor should run smoothly, and stop at Shut. If it does not, reverse the connections; the rear vent control motor should run smoothly, and stop at Rear Vent. When the rear vent control motor stops running, disconnect battery power immediately.
3. If the rear vent control motor did not run in step 2, remove it, then check the rear vent control linkage and the door for smooth movement.
- If the linkage and the door move smoothly, replace the rear vent control motor Rear Vent Control Motor Replacement.
- If the linkage or the door sticks or binds, repair them as needed.