Readiness Code, Generating
Readiness Code, Generating (> M.Y. 1997)
NOTE:
- Generate the readiness code for m.Y. 1998.
- There must be no malfunctions stored in DTC memory.
- During the procedure, the engine must not be stopped.
- If specified values are attained before the minimum time allowed, the test sequence may be advanced.
- Engine temperature at least 85 °C (185 °F).
- Connect VAG1551 or VAG1552 Scan Tool (ST) and press buttons -0- and -1- to insert "Engine Electronics" address word 01 (engine idling). [1][2]Scan Tool Connecting and Initial Checks
Step 1: Check DTC memory
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -2- to select "Check DTC Memory" function 02, and press -Q- button to confirm input.
Indicated on display
No DTC recognized
- Press -> button to advance program sequence.
Step 2: Erase DTC Memory
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -5- to select "Erase DTC Memory" function 05, and press -Q- button to confirm input.
Indicated on display
Rapid data transfer ->
DTC Memory is erased
- Press -> button to advance program sequence.
Step 3: Heated Oxygen Sensor (HO2S) and Heated Oxygen Sensor (HO2S) 2 (bank 1 and bank 2), readiness
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select "Read Measuring Value Block" function 08, and press -Q- button to confirm input.
Indicated on display
Read Measuring Value Block
Input display group number XXX
- Press buttons -0-, -2- and -6- to input display group number 26 (026), and press -Q- button to confirm input.
Indicated on display
Read Measuring Value Block 26 ->
1 2 3 4
- Specified value in display field 3: "B1-S1 ON" (after 5 min.)
- Specified value in display field 4: "B2-S1 ON" (after 5 min.)
If "OFF" appears in display field 3 or 4:
- Check heated oxygen sensor and oxygen sensor heater.
Refer "Oxygen Sensor (O2S) Control, Checking"
Refer "Oxygen Sensor (O2S) Heating, Checking"
- Press buttons -0- and -4- to select "Basic Setting" function 04.
- Press -3- button three times (VAG1551) to advance to display group 29.
Indicated on display
System in Basic Setting 29 ->
1 2 3 4
Step 4: Oxygen sensor aging diagnosis, Bank 1 and Bank 2
- Three way catalytic converter temperature greater than 300 °C (display field 2)
- Raise engine speed (display field 1) to between 1800 and 2200 RPM, and hold until display field 4 changes from "Test OFF" to "Test ON."
- Maintain RPM until display field 4 indicates "B1-S1 OK."
If display field 4 changes to "B1-S1 n.OK" check DTC memory.
- Press -3- button once to advance to display group 30.
Indicated on display
System in Basic Setting 30 ->
1 2 3 4
- Three way catalytic converter temperature greater than 300 °C (display field 2)
- Raise engine speed to between 1800 and 2200 RPM, and hold until display field 4 changes from "Test OFF" to "Test ON."
- Maintain RPM until display field 4 indicates "B2-S1 OK."
If display field 4 changes to "B2-S1 n.OK" check DTC memory.
- Press -3- button once to advance to display group 31.
Indicated on display
System In Basic Setting 31 ->
1 2 3 4
Step 5: Three Way Catalytic Converter (TWC) diagnosis, banks 1 and 2
- TWC temperature greater than 300 °C (display field 2)
- Raise engine speed to between 1800 and 2200 RPM, and hold until display field 4 changes from "Test OFF" to "Test ON."
Test duration approx. 60 seconds.
- Maintain RPM until display field 4 indicates "Cat B1 OK."
- If display field 4 changes to "Cat B1 n.OK" check DTC memory.
- Press -3- button once to advance to display group 32.
Indicated on display
System in Basic Setting 32 ->
1 2 3 4
- TWC temperature greater than 300 °C (display field 2)
- Raise engine speed to between 1800 and 2200 RPM and hold until display field 4 changes from "Test OFF" to "Test ON."
- Test duration approx. 60 seconds.
- Maintain RPM until display field 4 indicates "Cat B2 OK."
- If display field 4 changes to "Cat B2 n.OK" check DTC memory.
- Press -3- button once to advance to display group 33.
Indicated on display
System in Basic Setting 33 ->
1 2 3 4
Step 6: EVAP canister purge regulator valve diagnosis
- After diagnosis is selected, display field 4 must change from "Test OFF" to "Test ON."
- After diagnosis, value in display field 4 must be "EVAP OK."
NOTE: If during diagnosis the display changes from "Test ON" to "Test OFF" apply the throttle briefly to start the test again.
- If display field 4 changes to "EVAP n.OK" check DTC memory.
- Press -> button to advance program sequence.
Indicated on display
Rapid data transfer HELP
Select function XX
When all display fields indicate "0" and no malfunctions are stored in DTC memory, the OBD II function check is successful.
- Press -> button to advance program sequence.
- Press buttons -0- and -6- to select "End Output" function 06, and press -Q- button to confirm input.
- Press buttons -0- and -8- to select function "Read Measuring Value Block" function 08, and press -Q- button to confirm input.
Indicated on display
Read Measuring Value Block
Input display group number XXX
- Press buttons -0-, -3- and -6- to input display group number 36 (036), and press -Q- button to confirm input.
Indicated on display
Read Measuring Value Block 36 ->
1 2 3 4