Operation CHARM: Car repair manuals for everyone.

Measuring Value Blocks (Function 08)




Read Measuring Value Block (Scan Tool Function 08)

Automatic vertical headlight aim control system

Initiating "Read Measuring Value Block" function 08


Indicated on display


Rapid data transfer HELP
Select function XX



- Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.

Indicated on display


Rapid data transfer Q
08 - Read Measuring Value Block



- Press -Q- button to confirm input.

Indicated on display

Read Measuring Value Block HELP
Input display group number XXX



- Input display group number from table.
- Press -Q- button to confirm input.

The VAG 1551 scan tool display now indicates the selected display group in standardized form.

List of display groups

Display group number Indicated on display

001 1 = Voltage supply terminal 15 V
2 = Low beam voltage supply through terminal 56b(V)
3 = Vehicle speed in km/h

002 1 = Vehicle level sensor front(V)
2 = Vehicle level sensor rear (V)
3 = Position motor actuation


Display Group 001:






Display Group 002: