Readiness Code Checking
Readiness Code, Checking
Test sequence
- Connect VAS5051 tester or VAG1551 scan tool and select the control module for engine electronics using address word 01. Connecting VAS 5051/VAG1551 Scan Tool
Ignition must remain switched on for this.
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select "Read Measuring Value Block" and press -Q- button to confirm input.
Indicated on display:
Read Measuring Value Block Q
Input display group number XXX
- Press buttons -0-, -8- and -6- to select "display group number 086" and press -Q- button to confirm input.
Indicated on display:
Read Measuring Value Block 86 ->
1 2 3 4
- Check readiness code in display field 1
- Specification: 00000000
Significance of 8 digit number block for readiness code in display field 1
NOTE: Readiness code is not generated unless all indicated positions display a 0.
If specified value "00000000" is obtained:
- Press -> button.
Indicated on display (function selection):
Rapid data transfer HELP
Select function XX
If specified value is not obtained:
- Generate readiness code Readiness Code, Generating