Combination Valve, Checking for Function and Leaks
Combination Valve, Checking for Function and Leaks
Special tools, testers and auxiliary items required
• Hand Vacuum Pump (VAS 6213)
Test Conditions
• Vacuum lines and hose connections free of leaks.
• Vacuum lines not plugged.
Test Sequence
- Remove rear engine cover - arrows -.
- Disconnect vacuum hose - arrow - at combination valve to be tested.
• Left combination valve is shown in illustration.
- Connect (VAS 6213) to the vacuum hose of the combination valve to be checked.
- Loosen quick-release fasteners - 1 and 2 - and remove front noise insulation.
- Disconnect pressure hose - arrow - at Secondary Air Injection (AIR) pump motor (V101).
- Blow with light pressure into pipe (do not use pressurized air).
• Both combination valves must be closed, it must not be possible to blow through hose.
- Operate the hand vacuum pump.
• The relevant combination valve must open, it must be possible to blow through
If relevant combination valve does not open:
- Replace combi-valve. Refer to => [ Left Combination Valve for Secondary Air Injection (AIR) ] Left Combination Valve for Secondary Air Injection (AIR) and => [ Right Combination Valve for Secondary Air Injection (AIR) ] Right Combination Valve for Secondary Air Injection (AIR).