Read Readiness Code
Readiness Code, Reading
Work sequence
- Connect VAS5051 tester, Vehicle Diagnostic, Testing and Information System VAS 5051, Connecting and Selecting Functions and select vehicle system "01 - Engine electronics". Engine must run at idle during this.
Display on VAS5051:
- Select diagnostic function "08 - read measured value block" in selection -1-.
Display on VAS5051:
1 - Enter display group
- Select function "086" in button field -2- for "display group number 086" and press Q button to confirm input.
Display on VAS5051:
- Check indication in display field 1.
- Specified value: 0 0 0 0 0 0 0 0
Note for display field 1:
Display field 1 is the most important. This indicates which system was checked via On Board Diagnostic (OBD) since the last time the DTC memory was erased or a new control module was implemented. Once the DTC memory is erased, all test table values are set to "1", after the test is performed successfully, the values are set to "0".
NOTE: The readiness code is not generated until all indications in display field 1 display "0" Once the specified value "00000000" is reached in display field 1:
- Click on <- button
If specified value is not obtained:
- Generate readiness code. Generate Readiness Code