Programming and Relearning
Basic Setting
With ignition on and engine at standstill, the following operations can be performed using "function 04", basic setting:
- Adapt throttle valve control module to Engine Control Module (ECM), See Display group 060
With engine running, the following operations can be performed using basic setting:
- Adaptation of oxygen sensor control
Requirements
- No DTCs in DTC memory.
- Coolant Temperature at least 80 degrees C.
- Electrical consumers switched off (radiator coolant fan must NOT run during test).
- A/C switched off.
Work sequence
- Connect VAS5051 tester, Vehicle Diagnostic, Testing and Information System VAS 5051, Connecting and Selecting Functions and select vehicle system "01 - Engine electronics". Ignition must be switched on for this, or, depending on desired operation:
- Start engine.
Display on VAS5051:
- In selection -1-, click on diagnostic function "04 - Basic Setting".
Display on VAS5051:
1 - Enter display group Max. input value = 255
- Enter desired 3-digit display group number in button field -2- and press -Q- button to confirm input. Example:
- Press buttons -0-, -0- and -0- to select "display group number 000" and press -Q- button to confirm input.
NOTE: After selecting display group number, the EVAP valve is closed and A/C compressor switched off.
Display on VAS5051:
1 - Display group 0
2 - Display field 1 2 3 4 5 6 7 8 9 10
- End function "04 - Basic setting" by pressing <- button.