Adaptation
Adaptation
• The idling speed can be decreased or increased by using the " Adaptation" function, channel 01.
• Only perform the idling speed adaptation described in the following: in order to eliminate vibration noises or they are the cause of a customer complaint.
Procedure
- Connect vehicle diagnostic, testing and information system (VAS5051). Refer to => [ VAS 5051, Connecting and Select Functions ] VAS 5051, Connecting and Select Functions and select vehicle system "01 - Engine electronics" in selection. Engine must be running at idling speed.
Display on (VAS5051):
- Under - 1 - select diagnostic function "10 - Adaptation".
Display on (VAS5051):
1. Enter channel number
- Enter "01" for "Adaptation channel 011" and confirm by pressing Q button.
Display on (VAS5051):
1. Read out and test
channel X
2 Display text of selected channel
or
No display
5 The scroll bar indicates the current adaptation value
• Adaptation value 128 is the factory-set idling speed,
• Adaptation can be performed by moving the scroll bar or by simply entering the new adaptation value.
A - Changing adaptation value using scroll bar
Display on (VAS5051):
- Move scroll bar - 5 - in desired direction or click on area next to scroll bar, which will move it in desired direction.
- Press "Save" button 4.
Display on (VAS5051):
1 Save channel X
2 Display text of selected channel or No display
4 Original value X, New value X
- Confirm new adaptation value by pressing "Accept" button 3.
Display on (VAS5051):
1. Channel X
Value X stored
- Exit function "10 - Adaptation" by pressing arrow button.
• An engine speed decrease follows immediately, an increase in engine speed is only effective after briefly pressing the accelerator pedal.
B - Adaptation by direct entry
Display on (VAS5051):
- Press "Keypad" button 3.
Display on (VAS5051):
1. Enter adaptation value
- Enter desired 5-digit adaptation value in zone - 2 - and confirm entry by pressing Q button.
Display on (VAS5051):
1 Save, channel X
2 Display text of selected channel or No display
4 Original value X, new value X
- Confirm new adaptation value by pressing "Accept" button 3.
Display on (VAS5051):
1. Channel X
Value X saved
- Exit function "10 - Adaptation" by pressing arrow button.
• Immediately following an engine speed decrease, an increase in engine speed is only effective after briefly pressing the accelerator pedal.