Intake Manifold Change-Over Valve, Checking
Diagnostic Procedures
Intake Manifold Change-Over Valve, Checking
Overview: Intake manifold change-over
Electrical Test
- Disconnect connector from Intake Manifold Change-Over Valve (N156).
- Perform a resistance measurement between the valve terminals using portable multimeter (VAG1526).
Specified value: 25 to 35 ohms
If specified value is not obtained.
- Replace Intake Manifold Change-Over Valve (N156).
If specified value is obtained.
- Check voltage supply.
Voltage Supply, Checking
- Connect voltage test lamp (VAG1527) between connector terminal 2 and engine Ground (GND) using adapter cables from connector test kit (VAG1594).
- Switch ignition on.
LED must light up.
- LED does not light up.
- Check fuse for intake manifold change-over valve (relay- and fuse holder in instrument panel, right side).
If fuse is OK.
- Check wire connection from terminal 2 of connector for intake manifold change-over valve via fuse to Motronic Engine Control Module (ECM) Power Supply Relay (J271) (relay carrier in E-box in plenum chamber) for open circuit/short circuit.
If voltage supply is OK, check wire connection.
Wire Connections, Checking
- Connect test box (VAG1598/31) to wiring harness of Engine Control Module (ECM), refer to Repair Information.
- Check the following wire connection for open circuit/short circuit:
- Repair open circuit in wiring or short circuit if necessary.
- If wire connection is OK, replace Engine Control Module (ECM), refer to Repair Information and generate readiness code again => [ Readiness Code, Generating ] Monitors, Trips, Drive Cycles and Readiness Codes.
- Check intake manifold once again for function => [ Intake Manifold Change-Over, Checking Function ]. Intake Manifold Change-Over, Checking Function