Emergency Release Operating Mechanism
Emergency Release Operating Mechanism
Removing
• Shift mechanism function unit removed.
- Remove bolts - 1 - and remove actuator mechanism.
Installing
- To assemble actuator mechanism, Insert sliding bracket - 3 - with the tabs - arrows A - into cut-outs - arrows B - of the cover - 2 -.
- Clip end of Bowden cable - 4 - into sliding bracket and bracket into cover.
- Secure assembled actuator mechanism to shift mechanism function unit.
• Flat part - arrow C - faces toward connecting wires.