Selector Lever Handle and Shift Mechanism Cover Overview
Selector Lever Handle and Shift Mechanism Cover Overview
• Coat the bearings and the sliding surfaces with polycarbamide grease (G 052 142 A2).
1 Guide for Cover
• Pry out both halves of retaining tabs to disconnect, refer to => [ ] Service and Repair
2 Cover
• With solenoid for Tiptronic switch (F189) on the tambour door.
• Removing and installing, refer to => [ ] Service and Repair
3 Frame with Circuit Board
• Can only be replaced as a unit
• With integrated Tiptronic switch
• With symbol illumination switches
• If switches malfunction, first check whether respective solenoid is secured correctly to the cover strip - 2 -, replace cover strip if necessary
• Check the circuit board in guided fault finding
• Removing and installing, refer to => [ ] Service and Repair
• Before replacing the circuit board for error message 18161 in the fault memory, first check the adjustment of the selector lever cable, refer to => [ Selector Lever Cable, Checking and Adjusting ] Procedures
4 Selector Lever Handle
• Refer to => [ Selector Lever Handle ] Selector Lever Handle
5 Selector Lever Sleeve
• Removing and installing, refer to => [ Selector Lever Handle ] Selector Lever Handle
6 Cover Molding with Symbol Panel
• Removing and installing, refer to => [ ] Service and Repair
7 Symbol Illumination Switch Solenoid
8 Tiptronic Recognition Switch Solenoid