Air Injection Control Valve: Service and Repair
Secondary Air Injection Combination Valves
Removing
- Open the quick-release fasteners - 1 - and remove the front noise insulation.
- Remove air guide hose from secondary air injection pump - arrow -.
- Remove the vacuum hoses - 2 - and - 3 -.
- Remove bolts - 1 - and - 6 - and remove connecting piece.
- Remove air guide hoses - 4 - and - 5 -.
- Remove affected secondary air injection combi-valve.
Installing
Installation is in reverse order of removal, note the following:
• Replace seals.
Tightening Specifications