Operation CHARM: Car repair manuals for everyone.

Secondary Injection Combination Valves, Checking For Function and Leaks






Secondary Injection Combination Valves, Checking for Function and Leaks

Special tools, testers and auxiliary items required

Hose Clamps up to 25 mm Dia. (3094) for the left Secondary Air Injection (AIR) combination valve

Hand Vacuum Pump (VAS 6213)

Procedure

Vacuum lines and hose connections free of leaks.

Vacuum lines not plugged.

Left secondary air injection (AIR) combi-valve:





- Remove the air guide tube - arrows -.

Ignore - 1 -.

- Remove the rear vacuum hoses - 1, 2, 4 - from the intake manifold.





- Remove wiring connection from intake manifold - arrows - and lay back with hoses connected.

Ignore - 3 -.

- Remove the Secondary Air Injection (AIR) hose - arrow -, pull it up and clamp it off with the (3094).





- Disconnect the vacuum hose from the Secondary Air Injection (AIR) combination valve.





- Connect the (VAS 6213) to the Secondary Air Injection (AIR) combination valve vacuum connection.

- Disconnect the Secondary Air Injection (AIR) hose the marked location - arrow -.





- Blow into the Secondary Air Injection (AIR) hose using light pressure (do not use pressurized air).

Secondary Air Injection (AIR) combination valve must be closed, it must not be possible to blow through.

- Run the hand vacuum pump to generate a vacuum.

The Secondary Air Injection (AIR) combination valve must open, it must be possible to blow through.

- If the left Secondary Air Injection (AIR) combination valve does not react as described, replace it=> [ Secondary Air Injection Left Combination Valve ] Secondary Air Injection Left Combination Valve.

Right secondary air injection (AIR) combi-valve:





- Remove the right secondary air injection combination valve. Refer to => [ Secondary Air Injection Right Combination Valve ] Secondary Air Injection Right Combination Valve.

- Connect the Hand Vacuum Pump (VAS 6213) to the right Secondary Air Injection (AIR) combination valve vacuum connection - 1 -.

- Connect a suitable assisting hose to the secondary air combination valve - 2 -.

- Blow lightly into the assisting hose by mouth, do not use compressed air.

Secondary Air Injection (AIR) combination valve must be closed, it must not be possible to blow through.

- Run the hand vacuum pump to generate a vacuum.

The Secondary Air Injection (AIR) combination valve must open, it must be possible to blow through.

- If the right Secondary Air Injection (AIR) combination valve does not react as described, replace it. Refer to => [ Secondary Air Injection Right Combination Valve ] Secondary Air Injection Right Combination Valve.

Assembling

Assembly is in reverse order of removal, note the following:

- Install the right secondary air injection combination valve. Refer to => [ Secondary Air Injection Right Combination Valve ] Secondary Air Injection Right Combination Valve.