Secondary Injection Combination Valves, Checking For Function and Leaks
Secondary Injection Combination Valves, Checking for Function and Leaks
Special tools, testers and auxiliary items required
• Hose Clamps up to 25 mm Dia. (3094) for the left Secondary Air Injection (AIR) combination valve
• Hand Vacuum Pump (VAS 6213)
Procedure
• Vacuum lines and hose connections free of leaks.
• Vacuum lines not plugged.
Left secondary air injection (AIR) combi-valve:
- Remove the air guide tube - arrows -.
• Ignore - 1 -.
- Remove the rear vacuum hoses - 1, 2, 4 - from the intake manifold.
- Remove wiring connection from intake manifold - arrows - and lay back with hoses connected.
• Ignore - 3 -.
- Remove the Secondary Air Injection (AIR) hose - arrow -, pull it up and clamp it off with the (3094).
- Disconnect the vacuum hose from the Secondary Air Injection (AIR) combination valve.
- Connect the (VAS 6213) to the Secondary Air Injection (AIR) combination valve vacuum connection.
- Disconnect the Secondary Air Injection (AIR) hose the marked location - arrow -.
- Blow into the Secondary Air Injection (AIR) hose using light pressure (do not use pressurized air).
• Secondary Air Injection (AIR) combination valve must be closed, it must not be possible to blow through.
- Run the hand vacuum pump to generate a vacuum.
• The Secondary Air Injection (AIR) combination valve must open, it must be possible to blow through.
- If the left Secondary Air Injection (AIR) combination valve does not react as described, replace it=> [ Secondary Air Injection Left Combination Valve ] Secondary Air Injection Left Combination Valve.
Right secondary air injection (AIR) combi-valve:
- Remove the right secondary air injection combination valve. Refer to => [ Secondary Air Injection Right Combination Valve ] Secondary Air Injection Right Combination Valve.
- Connect the Hand Vacuum Pump (VAS 6213) to the right Secondary Air Injection (AIR) combination valve vacuum connection - 1 -.
- Connect a suitable assisting hose to the secondary air combination valve - 2 -.
- Blow lightly into the assisting hose by mouth, do not use compressed air.
• Secondary Air Injection (AIR) combination valve must be closed, it must not be possible to blow through.
- Run the hand vacuum pump to generate a vacuum.
• The Secondary Air Injection (AIR) combination valve must open, it must be possible to blow through.
- If the right Secondary Air Injection (AIR) combination valve does not react as described, replace it. Refer to => [ Secondary Air Injection Right Combination Valve ] Secondary Air Injection Right Combination Valve.
Assembling
Assembly is in reverse order of removal, note the following:
- Install the right secondary air injection combination valve. Refer to => [ Secondary Air Injection Right Combination Valve ] Secondary Air Injection Right Combination Valve.