Defect Code 19
Defect Code 19:
Explanation:
Plunger accumulator pressure too low or signal for plunger warning pressure threshold faulty
Possible cause:
Short to positive on the pressure signal wire from plunger hydraulic unit to the ABS/ASC+T control unit
Break or short to ground on the warning pressure signal wire from plunger hydraulic unit to the ABS/ASC+T control unit
Troubleshooting:
Switch on ignition and measure voltage at the control unit connector (X11) Pin 13; Nominal value: <1.5 V or >3.5 V;
Nominal value OK.:
- Remove plunger hydraulic unit.
- Ensure plug connections are firmly fitted and check for corrosion.
- Check warning pressure signal wire from control unit connector (X11) Pin 25 to pressure sensor connector (X18025) Pin 6 and repair if necessary.
Nominal value not OK.:
- Remove plunger hydraulic unit.
- Ensure plug connections are firmly fitted and check for corrosion.
- Check B+ supply wire from control unit connector (X11) Pin 17 to pressure sensor connector (X18025) Pin 5 and repair if necessary.
- Check pressure signal wire from control unit connector (X11) Pin 13 to pressure sensor connector (X18025) Pin 1 and repair if necessary.
- Check ground wire to pressure sensor connector (X18025) Pin 2 and repair if necessary.