Operation CHARM: Car repair manuals for everyone.

P0111

System/Component
Temperature Sensor (intake air)

Fault Code
P0111

Fault Type
Plausibility No
Signal Yes
Minimum Threshold Yes
Maximum Threshold Yes

Monitoring Method
Voltage range check

Signal Type
Non-pulsating signal

Operating Range
-42°C to 148°C

Time Length and Frequency for Monitoring/Diagnosis
0.5 sec/permanent

Criteria for storing fault code
fault during 2 trips

Criteria for illuminating the MIL
fault during 2 trips and end of 2nd trip

Criteria used for determining out of range values and input component rationality check
UBATT Yes
Ground Yes
Disconnect Yes

Electronic Control Module (ECM)
U < 0.23V
U > 4.92V