P0116
System/ComponentTemperature Sensor (coolant)
Fault Code
P0116
Fault Type
Plausibility No
Signal Yes
Minimum Threshold Yes
Maximum Threshold Yes
Monitoring Method
Voltage Range Check
Signal Type
Non-pulsating signal
Operating Range
-40°C to 142°C
Time Length and Frequency for Monitoring/Diagnosis
0.5 sec/permanent
Criteria for storing fault code
fault during 2 trips
Criteria for illuminating the MIL
fault during 2 trips and end of 2nd trip
Criteria used for determining out of range values and input component rationality check
UBATT Yes
Ground Yes
Disconnect Yes
Electronic Control Module (ECM)
U < 0.285V
U > 4.94V