P1519
System/ComponentVariable Camshaft Timing (VANOS)
Fault Code
P1519
Fault Type
Plausibility Yes
Signal No
Minimum Threshold No
Maximum Threshold No
Monitoring Method
Plausibility check
Signal Type
ECM internal signal/value computation or comparison
Operating Range
± 12.5° cam angle
Time Length and Frequency for Monitoring/Diagnosis
Once per revolution/permanent
Criteria for storing fault code
fault during 2 trips
Criteria for illuminating the MIL
fault during 2 trips and end of 2nd trip
Criteria used for determining out of range values and input component rationality check
UBATT No
Ground No
Disconnect No
Electronic Control Module (ECM)
At engine speed > 900 rpm, the actual camshaft timing is compared to the estimated values.
VANOS inactive: Fault if timing is greater than ± 3° camshaft angle from estimated value.
VANOS active: Fault if timing is greater than ± 4.5° camshaft angle from estimated value.