Operation CHARM: Car repair manuals for everyone.

Camshaft Position (CMP) Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right) Intake



CAMSHAFT POSITION (CMP) ACTUATOR SOLENOID VALVE SOLENOID REPLACEMENT - BANK 1 (RIGHT) INTAKE

REMOVAL PROCEDURE
1. Turn the ignition OFF.
2. Remove the power steering pressure hose bracket and reposition the hose as necessary in order to gain access.




3. Remove the camshaft position (CMP) actuator valve electrical connector (1).




4. Remove the CMP actuator valve bolt.
5. Remove the CMP actuator valve.

INSTALLATION PROCEDURE




1. Install the CMP actuator valve.

NOTE: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

2. Install the CMP actuator valve bolt.

Tighten the CMP actuator valve bolt to 10 Nm (89 lb in).




3. Install the CMP actuator valve electrical connector (1).
4. Install the power steering pressure hose bracket and nut as necessary.