System Diagnosis - EVAP Control
CONDITIONS FOR SETTING THE DTC
^ No Throttle Position (TP) sensor, Output Driver Module (ODM), Intake Air Temperature (IAT) sensor, or Manifold Absolute Pressure (MAP) sensor DTCs set.
^ The DTC P0442 diagnostic test has passed.
^ A continuous open purge flow condition is detected during the diagnostic test (fuel tank pressure decreases to less than -11 in. H20).
ACTION TAKEN WHEN THE DTC SETS
^ The PCM will illuminate the Malfunction Indicator Lamp (MIL) during the first trip in which the diagnostic test has been run and failed.
^ The PCM will store conditions which were present when the DTC set as Freeze Frame and Fail Records data.
Important: Although these diagnostics are considered type A, they act like type B diagnostics under certain conditions. Whenever the [1][2]EVAP diagnostics report that the system has passed, or if the battery has been disconnected, the diagnostic must fail during two consecutive cold start trips before setting a DTC. The initial failure is not reported to the diagnostic executive or displayed on a scan tool. A passing system always reports to the
CONDITIONS FOR CLEARING THE MIL/DTC
^ The PCM will turn the MIL OFF during the third consecutive trip in which the diagnostic has been run and passed.
^ The history DTC will clear after 40 consecutive warm-up cycles have occurred without a malfunction.
^ The DTC can be cleared by using the scan tool Clear Info function or by disconnecting the PCM battery feed.
DIAGNOSTIC AIDS
Check for the following conditions:
^ Poor connection at the PCM.
Inspect harness connectors for backed out terminals, improper mating, broken locks, improperly formed or damaged terminals, and poor terminal to wire connection.
^ Damaged harness.
Inspect the wiring harness for damage.
^ If the harness appears to be OK, connect the J 41413.
^ Incorrect vacuum line routing.
Verify that the source vacuum line routing to the [1][2]EVAP purge valve is correct and that the EVAP purge and source vacuum lines to the EVAP purge valve are not switched.
^ Malfunctioning or damaged canister.
A malfunctioning canister may intermittently allow charcoal into the [1][2]EVAP purge valve, EVAP vacuum switch, and associated lines causing a DTC to be set. Use the following procedure to check for a carbon release condition:
1. Turn OFF the ignition switch.
2. Remove the [1][2]EVAP purge valve. Refer to EVAP Canister Purge Solenoid / Service and Repair.
3. Lightly tap the [1][2]EVAP purge valve and (if applicable) the vacuum switch on a clean work area looking for carbon particles exiting either of the vacuum ports.
4. If no carbon release is evident, reinstall the components and continue with the DTC P1441 table. If carbon is being released from either component, continue with this service procedure.
P1441
5. Remove the EVAP canister from the vehicle.
6. Ensure that the main cylinder valve is turned off on the J 41413
7. Disconnect the black hose that connects the nitrogen cylinder to the [1][2]EVAP purge/pressure diagnostic station at the pressure regulator by unscrewing the knurled nut on the regulator. No tools are required to remove the black hose from the regulator.
8. Using a section of vacuum line, connect one end over the open threaded fitting of the [1][2]EVAP purge/pressure diagnostic station pressure regulator.
9. Connect the remaining end to the [1][2]EVAP purge valve end of the EVAP purge line at the vehicle and turn on the main nitrogen cylinder valve. Continue to blow any debris from the purge line for 15 seconds.
10. Return the [1][2]EVAP Pressure/Purge Diagnostic Station to its original condition by re-installing the black hose that was disconnected in step 7.
11. Replace the following components:
- The [1][2]EVAP purge valve. Refer to EVAP Canister Purge Solenoid / Service and Repair.
- The EVAP canister. Refer to Evaporative Emission Control Canister Replacement.
12. Proceed with the the DTC P1441 diagnostic table.
Reviewing the Fail Records vehicle mileage since the diagnostic test last failed may help determine how often the condition that caused the DTC to set occurs. This may assist in diagnosing the condition.
TEST DESCRIPTION
Number(s) below refer to the step number(s) on the Diagnostic Table.
5. The PCM will command the [1][2]EVAP purge and EVAP canister vent valves closed with the scan tool Seal System EVAP output control function activated. Fuel tank pressure should not decrease under this condition.
6. The PCM commands the [1][2]EVAP purge valve OFF (open) and the EVAP canister vent valve ON (closed) with the scan tool System Perf. EVAP output control function activated. Engine vacuum should cause fuel tank pressure to decrease when System Perf. is activated.