Air Compressor Leak Test - ALC
Air Compressor Leak Test^ Tools Required
- J22124-B Pressure Gage (0-300 psi)
- J 22124-91 Pressure Gage Adapter
1. Attach the J22124-91 to the air dryer.
2. Attach the J 22124-B to the J22124-91 with toggle valve on the opposite side of the air compressor. Close the toggle valve.
3. Apply air pressure at the schrader valve. Pressurize until the J 22124-B reads 690 kPa (100 psi).
4. Check the following areas using soap bubbles:
^ Solenoid valve
Replace the air compressor head if leaking.
^ Air dryer to compressor head O-ring
Replace the air dryer if leaking.
^ Air dryer cover
Replace the air dryer if leaking.
^ Air compressor head gasket
Replace the air compressor head if leaking.
^ Air compressor head cover gasket