HVAC System

CIRCUIT DESCRIPTION
The LH temperature valve actuator is a DC stepper motor by design. The stepper motor has four field windings that are controlled by the heater and A/C control. When the heater and A/C control needs to move the stepper motor, it energizes the proper field windings which rotates the armature a fixed amount in the proper direction. This fixed amount is called a step. Battery voltage for the stepper motor is supplied by the heater and A/C control when the ignition is in the ON position.

Attached to the stepper motor is a small gear. When the stepper motor is installed on the HVAC module, it meshes with a larger gear which is pan of an assembly that drives the linkage of the air mix door.

CONDITIONS FOR SETTING THE DTC
The heater and A/C control, measures the current of all four coil wires of the stepper motor within 10 seconds when the ignition is in the ON position. The measured current is averaged by the controller and a "fail threshold" is calculated. After the output current is measured it is compared with the threshold value. If a short circuit to battery is detected on any of the low side drivers, the controller automatically protects the low side drivers by disabling all low side outputs. This step is repeated 3 times within the 10 second time frame.

ACTION TAKEN WHEN THE DTC SETS
^ Stores a DTC 19 in the heater and A/C control memory.
^ The fault detection process is repeated 3 times at a fixed interval of 70 ms to allow for debouncing.
When the fault is set, the stepper motor can no longer be controlled.

CONDITIONS FOR CLEARING THE DTC
^ The conditions for the fault are no longer present.
^ Using a scan tool.
^ A history DTC will clear after 20 consecutive ignition cycles if the conditions for the fault is no longer present.

DIAGNOSTIC AIDS
If condition not present, refer to Testing for Intermittent and Poor Connections in Diagrams.

TEST DESCRIPTION

Steps 1-4:




Steps 5-12:




Steps 13-25:




The numbers below refer to the step numbers on the diagnostic table.
2. Tests to ensure that the heater and A/C control has the ability to command the LH temperature valve actuator.
5. Tests for the proper operation of the circuit in the high voltage range when the actuator is at rest.
6. Tests for the proper operation of the circuit in the high voltage range when the actuator is at rest.
7. Ensures the heater and A/C control has the ability to control the LH temperature valve actuator.
8. Ensures the heater and A/C control has the ability to control the LH temperature valve actuator.
9. Ensures the heater and A/C control has the ability to control the LH temperature valve actuator. Test lamp will be illuminated when connection made. Test lamp should increase intensity when commanded.
10. Ensures the heater and A/C control has the ability to control the LH temperature valve actuator. Test lamp will be illuminated when connection made. Test lamp should increase intensity when commanded.
11. Verifies the heater and A/C control is getting power from fuse CLAMP 15 Fuse 14.