HVAC System
CIRCUIT DESCRIPTIONWhen the A/C button is pressed ON, battery voltage is supplied to terminal 2 of the A/C compressor refrigerant pressure switch. The A/C pressure switch is closed when the pressure in the refrigerant line is approximately 180 kPa (36 psi). With the pressure switch closed, battery voltage is supplied to terminal 58 connector C2 of the Engine Control Module (ECM). After receiving the A/C request input, the ECM grounds the A/C compressor relay coil which energizes the relay closing the relay contacts. With the relay contacts closed, the circuit is completed allowing battery voltage to be applied to the A/C compressor clutch coil. The A/C compressor clutch coil energizes and the compressor clutch will now engage.
The heater and A/C control monitors the state of the compressor clutch relay through the A/C cutout input circuit.
CONDITIONS FOR RUNNING THE DTC
^ The ignition is ON.
^ The A/C request is inactive.
CONDITIONS FOR SETTING THE DTC
The heater and A/C control detects an open or short to voltage in the A/C request circuit.
ACTION TAKEN WHEN THE DTC SETS
^ Stores a DTC 35 in the heater and A/C control memory.
^ The heater and A/C control does not disable the output.
CONDITIONS FOR CLEARING THE DTC
^ The condition for the fault is no longer present.
^ Using a scan tool.
^ A history DTC will clear after 20 consecutive ignition cycles if the condition for the fault is no longer present.
DIAGNOSTIC AIDS
If condition not present, refer to Testing for Intermittent and Poor Connections in Diagrams.
TEST DESCRIPTION
Steps 1-6:
Steps 7-16:
The number(s) below refer to the step number(s) on the diagnostic table.
2. This step determines if the malfunction is present.
3. This step verifies that refrigerant level is within specifications.
4. This step verifies that the A/C request circuits and the A/C compressor refrigerant pressure switch are not open.
5. This step tests for open contacts in the A/C compressor refrigerant pressure switch.
7. This step tests for a short to voltage in the A/C request circuits The voltage measurement at the ECM should drop from 12 volts to 6.5 volts when the A/C request is commanded from active to inactive.
8. This step verifies that the A/C compressor refrigerant switch is not internally shorted to voltage.