Air Delivery Improper
TEST DESCRIPTIONSteps 1-9:
Steps 10-19:
Steps 20-27:
Steps 28-36:
Steps 37-47:
Steps 48-57:
The numbers below refer to the step numbers on the diagnostic table.
7. Tests to ensure that the heater and A/C control has the ability to command the inside air valve actuator.
9. Tests for the proper operation of the circuit in the high voltage range when the actuator is at rest.
10. Tests for the proper operation of the circuit in the high voltage range when the actuator is at rest.
11. Ensures the heater and A/C control has the ability to control the inside air valve actuator.
12. Ensures the heater and A/C control has the ability to control the inside air valve actuator.
13. Ensures the heater and A/C control has the ability to control the inside air valve actuator. Test lamp will be illuminated when connection made. Test lamp should increase intensity when commanded.
14. Ensures the heater and A/C control has the ability to control the inside air valve actuator. Test lamp will be illuminated when connection made. Test lamp should increase intensity when commanded.
19. Tests to ensure that the heater and A/C control has the ability to command the mode valve actuator.
21. Tests for the proper operation of the circuit in the high voltage range when the actuator is at rest.
22. Tests for the proper operation of the circuit in the high voltage range when the actuator is at rest.
23. Ensures the heater and A/C control has the ability to control the mode valve actuator.
24. Ensures the heater and A/C control has the ability to control the mode valve actuator.
25. Ensures the heater and A/C control has the ability to control the mode valve actuator. Test lamp will be illuminated when connection made. Test lamp should increase intensity when commanded.
26. Ensures the heater and A/C control has the ability to control the mode valve actuator. Test lamp will be illuminated when connection made. Test lamp should increase intensity when commanded.
31. Tests to ensure that the heater and A/C control has the ability to command the defrost valve actuator.
33. Tests for the proper operation of the circuit in the high voltage range when the actuator is at rest.
34. Tests for the proper operation of the circuit in the high voltage range when the actuator is at rest.
35. Ensures the heater and A/C control has the ability to control the defrost valve actuator.
36. Ensures the heater and A/C control has the ability to control the defrost valve actuator.
37. Ensures the heater and A/C control has the ability to control the defrost valve actuator. Test lamp will be illuminated when connection made. Test lamp should increase intensity when commanded.
38. Ensures the heater and A/C control has the ability to control the defrost valve actuator. Test lamp will be illuminated when connection made. Test lamp should increase intensity when commanded.