Water Outlet Housing Replacement
Water Outlet Housing Replacement (LP1, LY7)
Removal Procedure
1. Partially drain the cooling system. Refer to Draining and Filling Cooling System (GE 47716) Draining and Filling Cooling System (LP1, LY7 Static Fill) Draining and Filling Cooling System (LS2 Static Fill).
2. Remove the radiator hose from the water outlet.
3. Remove the surge tank inlet hose from the water outlet housing.
4. Remove the water outlet housing bolts.
5. Remove the water outlet.
6. Remove and discard the water outlet seals.
7. Clean the water outlet housing sealing surfaces.
Installation Procedure
1. Install NEW water outlet housing seals.
2. Install the water outlet.
Notice: Refer to Fastener Notice.
3. Install the water outlet bolts.
Tighten the water outlet housing bolts to 10 N.m (89 lb in).
4. Install the surge tank inlet hose to the water outlet housing.
5. Install the radiator hose to the water outlet.
6. Fill the cooling system. Refer to Draining and Filling Cooling System (GE 47716) Draining and Filling Cooling System (LP1, LY7 Static Fill) Draining and Filling Cooling System (LS2 Static Fill).