Air Temperature Sensor Replacement - Lower Right Side
Air Temperature Sensor Replacement - Lower Right Side
Removal Procedure
1. Remove the HVAC module. Refer to HVAC Module Assembly Replacement (Service and Repair) .
Important: Rotate the DTM sensor counter-clockwise to disengage the sensor from the lower duct.
2. Disconnect the lower RH DTM sensor electrical connector.
3. Remove the lower RH DTM sensor from the HVAC module.
Installation Procedure
Important: Rotate the DTM sensor clockwise to engage the sensor to the lower duct.
1. Install the lower RH DTM sensor to the HVAC module.
2. Connect the lower RH DTM sensor electrical connector.
3. Install the HVAC module. Refer to HVAC Module Assembly Replacement (Service and Repair) .