Refrigerant Pressure Sensor / Switch: Service and Repair
Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement
Tools Required
J 39400-A Halogen Leak Detector
Removal Procedure
1. Remove the air cleaner assembly.
2. Disconnect the electrical connector from the A/C refrigerant pressure sensor.
3. Remove the A/C refrigerant pressure sensor from the evaporator tube.
Installation Procedure
1. Replace the O-ring seal for the A/C refrigerant pressure sensor.
Notice: Refer to Fastener Notice.
2. Install the A/C refrigerant pressure sensor to the evaporator tube.
Tighten the sensor to 4.7 N.m (41 lb in).
3. Connect the electrical connector to the A/C refrigerant pressure sensor.
4. Install the air cleaner assembly.
5. Leak test the fittings of the component using J 39400-A.