B2500
DTC B2500
Circuit Description
When the ignition switch is turned to ON, the sensing and diagnostic module (SDM) will perform a turn-on test to diagnose critical malfunctions within the SDM itself.
Upon passing these tests, ignition and deployment loop voltages are measured to ensure that they are within their normal voltage ranges. The SDM monitors the voltages at the driver low and the passenger low to detect shorts to ground or voltage in the deployment loops.
If the warning lamp operates properly ON and OFF, the SDM measures the voltage continuously from the warning lamp terminal.
DTC Descriptor
This diagnostic procedure supports the following DTC:
DTC B2500 Inflatable Restraint System Indicator Circuit
Conditions for Running the DTC
Ignition voltage is within the normal operating voltage range.
Conditions for Setting the DTC
The warning lamp does not blink properly ON and OFF.
Action Taken When the DTC Sets
The SDM commands the AIR BAG indicator ON.
Conditions for Clearing the DTC
The condition responsible for setting the DTC no longer exists and the scan tool Clear DTCs function is used.