Canister Purge Solenoid: Service and Repair
Evaporative Emission Canister Purge Solenoid Valve Replacement
Removal Procedure
1. Remove the intake manifold cover. Refer to Intake Manifold Cover Replacement (Service and Repair).
2. Disconnect the evaporative emission (EVAP) canister purge solenoid electrical connector (1).
3. Disconnect the chassis EVAP pipe from the EVAP canister purge solenoid. Refer to Plastic Collar Quick Connect Fitting Service (Plastic Collar Quick Connect Fitting Service).
4. Remove the EVAP canister purge valve bolt.
5. Remove the EVAP canister purge valve.
Installation Procedure
1. Remove the EVAP canister purge valve.
Caution: Refer to Fastener Caution (Fastener Caution).
2. Remove the EVAP canister purge valve bolt.
Tighten the bolt to 16 Nm (12 lb ft).
3. Connect the chassis EVAP pipe to the EVAP canister purge solenoid. Refer to Plastic Collar Quick Connect Fitting Service (Plastic Collar Quick Connect Fitting Service).
4. Connect the EVAP canister purge solenoid electrical connector (1).
5. Install the intake manifold cover. Refer to Intake Manifold Cover Replacement (Service and Repair).