Refrigerant Pressure Sensor / Switch: Service and Repair
Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement
Special Tools
J 39400-A - Halogen Leak Detector
Removal Procedure
1. Remove the air cleaner assembly. Refer to Air Cleaner Assembly Replacement Air Cleaner Assembly Replacement
2. Disconnect the electrical connector from the A/C refrigerant pressure sensor.
3. Remove the A/C refrigerant pressure sensor from the evaporator tube.
Installation Procedure
1. Replace the O-ring seal for the A/C refrigerant pressure sensor. Refer to Air Conditioning O-Ring Seal Replacement Air Conditioning O-Ring Seal Replacement.
Caution:
Refer to Fastener Caution Fastener Caution.
2. Install the A/C refrigerant pressure sensor to the evaporator tube and tighten to 4.7 Nm (41 lb in).
3. Connect the electrical connector to the A/C refrigerant pressure sensor.
4. Install the air cleaner assembly. Refer to Air Cleaner Assembly Replacement Air Cleaner Assembly Replacement
5. Leak test the fittings of the component using J 39400-A - Halogen Leak Detector.