U1414
U1414-IMPLAUSIBLE/MISSING ECU CONFIGURATION DATAWHEN MONITORED
With the ignition on. The ORC on board diagnostics continuously monitors the CAN Bus message from the Totally Integrated Power Module (TIPM) containing the ORC Configuration Data.
SET CONDITION
This DTC will set if the appropriate CAN Bus message is not received by the ORC.
POSSIBLE CAUSES
- Totally integrated power module (TIPM)
Diagnostic Test
1. TOTALLY INTEGRATED POWER MODULE FAILURE
Turn the ignition on.
With the scan tool, read TIPM DTCs.
Q: Does the scan tool display any TIPM DTCs?
YES: Select appropriate symptom from Symptom List. Repair all TIPM active DTCs and before diagnosing the ORC DTCs.
NO: Replace the Totally Integrated Power Module (TIPM). Perform ORC VERIFICATION TEST - VER 1. Occupant Restraint Controller (ORC) Verification Test