P0139
Tests 1 - 2:
Tests 3 - 6:
Test 7:
SYMPTOM
P0139 - 1/2 O2 SENSOR SLOW RESPONSE
WHEN MONITORED
With engine temperature > 147 °F, after reaching a vehicle speed of 10 mph, and the throttle remaining open (OFF idle) for two minutes, bring the vehicle to a stop, allow engine to idle with the transmission in Drive (auto) or in Neutral (manual).
SET CONDITION
The oxygen sensor signal voltage is switching from below 0.27 volts to above 0.62 volts and back fewer times than required.
POSSIBLE CAUSES
- 1/2 O2 sensor ground circuit open
- Oil or coolant consumption
- O2 sensor heater failure
- 1/2 O2 sensor
- 1/2 O2 sensor terminal
- Exhaust system leaks
- PCM terminal