P0251
Test 1 - 3:
Test 4 - 6:
SYMPTOM
P0251-CP3 PUMP REGULATOR CONTROL
WHEN MONITORED
When the ignition is on.
SET CONDITION
The ECM detects a discrepancy between the PWM supplied to the Electronic Fuel Control Actuator and the PWM returned from the Electronic Fuel Control Actuator.
POSSIBLE CAUSES
- Intermittent condition
- Fuel control actuator
- (K31) return circuit open from FCA to ECM
- (K65) 5-volt supply circuit open from FCA to ECM
- (K65) 5-volt supply circuit shorted to voltage
- ECM