Generator - Removal






3.7L / 4.7L










WARNING: Disconnect negative cable from battery before removing battery output wire (b+ wire) from generator. Failure to do so can result in injury or damage to electrical system.

1. Disconnect the negative battery cable.
2. Remove the generator drive belt Serpentine Accessory Drive Belt - Removal.
3. Unsnap the plastic insulator cap from the B+ output terminal (3).
4. Remove the B+ terminal mounting nut at the rear of generator (2). Disconnect the terminal from the generator.
5. Disconnect the field wire connector at the rear of the generator (4) by pushing on the connector tab.










6. Remove the one rear vertical generator mounting bolt (2).
7. Remove the two front horizontal generator mounting bolts (1).
8. Remove the generator from vehicle.