Operation CHARM: Car repair manuals for everyone.

Test A: The DC/AC Inverter Does Not Operate Correctly - No Power At The AC Power Point



PINPOINT TEST A: THE DC/AC INVERTER DOES NOT OPERATE CORRECTLY - NO POWER AT THE AC POWERPOINT

A1 - A2:





A3 - A4:






Normal Operation

NOTE:
- The electrical device that is powered by the AC Powerpoint must not exceed 150W.
- If the green LED is flashing, the AC Powerpoint may be overloaded, overheated, or shorted. Unplug the electrical device from the AC Powerpoint and cycle the key. Refer to the owner literature to determine if the electrical device is appropriate for the AC Powerpoint.

The DC/AC inverter receives 12 volts DC on circuits 3025 (YE/LG) and 1003 (GY/YE) and is grounded on circuit 57 (BK). The incoming DC power is internally converted to 60 cycle 110 volts AC power that is output to the AC powerpoint on circuits 432 (BK/PK) (power) and 464 (BK/PK) (neutral).

Possible Causes
- fuse(s)
- circuit 3025 (YE/LG) open
- circuit 1003 (GY/YE) open
- circuit 57 (BK) open
- circuit 432 (BK/PK) open
- circuit 464 (BK/PK) open
- DC/AC inverter
- AC powerpoint