Test W: No Power To The Scan Tool
PINPOINT TEST W: NO POWER TO THE SCAN TOOLW1:
W2-W3:
Normal Operation
The scan tool is connected to the data link connector (DLC) to communicate with the high speed controller area network (HS-CAN) and the medium speed controller area network (MS-CAN) communications network. Voltage for the scan tool is provided by circuit SBP20 (GN/RD). Ground is provided by circuits GD113 (BK/YE) and GD138 (BK/WH).
Possible Causes
- Fuse
- Circuit SBP20 (GN/RD) open
- Circuit GD113 (BK/YE) open
- Circuit GD138 (BK/WH) open
- Scan tool