Inspection and Verification
INSPECTION AND VERIFICATION1. Verify the customer concern by checking the air bag warning indicator in the instrument cluster. Refer to Prove Out the System.
2. Visually inspect for obvious signs of mechanical or electrical damage. Do not disconnect electrical connectors until directed to do so within the pinpoint test.
Visual Inspection Chart:
NOTE: The smart junction box (SJB) may also be identified as the generic electronic module (GEM).
3. If an obvious cause for an observed or reported concern is found, correct the cause (if possible) before proceeding to the next step.
4. NOTE: Make sure to use the latest scan tool software release.
If the cause is not visually evident, connect the scan tool to the data link connector (DLC).
5. NOTE:The vehicle communication module (VCM) LED prove out confirms power and ground from the DLC are provided to the VCM.
If the scan tool does not communicate with the VCM:
- check the VCM connection to the vehicle.
- check the scan tool connection to the VCM.
- refer to Information Bus (Module Communications Network), No Power To The Scan Tool, to diagnose no communication with the scan tool.
6. If the scan tool does not communicate with the vehicle:
- verify the ignition key is in the ON position.
- verify the scan tool operation with a known good vehicle.
- refer to Information Bus (Module Communications Network) to diagnose no response from the PCM.
7. Carry out the network test.
- If the scan tool responds with no communication for one or more modules, refer to Information Bus (Module Communications Network).
- If the network test passes, retrieve and record on-demand and continuous memory DTCs from the RCM.
8. If the DTCs retrieved are related to the concern, go to Supplemental Restraint System (SRS) DTC Chart. For all other DTCs, refer to Body Control Systems (Multifunction Electronic Control Module). Diagnostic Trouble Code Tests and Associated Procedures
9. If no DTCs related to the concern are retrieved, GO to Symptom Chart. Symptom Related Diagnostic Procedures