Pinpoint Tests BC: DTC U0151
Instrumentation, Message Center and Warning Chimes
Pinpoint Tests
Pinpoint Test BC: DTC U0151
Normal Operation
- DTC U0151 (Lost Communication With Restraints Control Module) - sets in continuous memory in the Instrument Cluster (IC) if data messages received from the Restraints Control Module (RCM) over the High Speed Controller Area Network (HS-CAN) are missing. For a complete list of all network messages, refer to Information Bus.
This pinpoint test is intended to diagnose the following:
- RCM
- IC
PINPOINT TEST BC: DTC U0151
-------------------------------------------------
BC1 VERIFY THE CUSTOMER CONCERN
- Ignition ON.
- Verify that there is an observable symptom present.
- Is an observable symptom present?
Yes
GO to BC2.
No
The system is operating normally at this time. The DTC may have been set due to high network traffic or an intermittent fault condition.
-------------------------------------------------
BC2 CHECK THE COMMUNICATION NETWORK
- Ignition ON.
- Enter the following diagnostic mode on the scan tool: Network Test .
- Carry out the network test.
- Does the RCM pass the network test?
Yes
GO to BC3.
No
REFER to Information Bus.
-------------------------------------------------
BC3 RETRIEVE THE RECORDED DTCs FROM THE IC SELF-TEST
- Check for recorded IC DTCs from the self-test.
- Is DTC B1317 or DTC B1318 recorded?
Yes
GO to Pinpoint Test AR (B1317) or GO to Pinpoint Test AS (B1318). Pinpoint Tests AR: DTC B1317 Pinpoint Tests AS: DTC B1318
No
GO to BC4.
-------------------------------------------------
BC4 RECHECK THE IC DTCs
- Clear the DTCs. Repeat the IC self-test.
- Is DTC U0151 still present?
Yes
GO to BC5.
No
The system is operating correctly at this time. The DTC may have been set due to high network traffic.
-------------------------------------------------
BC5 CHECK FOR DTC U0151 SET IN OTHER MODULES
- Clear all DTCs.
- Ignition OFF.
- Ignition ON.
- Wait 10 seconds.
- Enter the following diagnostic mode on the scan tool: Self-Test .
- Retrieve the continuous memory DTCs from all modules.
- Is DTC U0151 set in the Occupant Classification System Module (OCSM)?
Yes
INSTALL a new RCM. REFER to Restraint Systems. CLEAR the DTCs. REPEAT the self-test.
No
INSTALL a new IC. REFER to Instrument Cluster (IC) Instrument Cluster (IC). TEST the system for normal operation.
-------------------------------------------------