C0564
DTC C0564Test 1-4:
Circuit Description
The electro-hydraulic power steering (EHPS) operates when voltage at the EHPS connector is in the range of 34-50 volts. The EHPS will go into standby mode if the supply voltage at the EHPS connector drops below 18 volts for more than 10 milliseconds. The EHPS module shall be turned back on once the supply voltage rises above 22 volts, without a key cycle being required. If the supply voltage drops below 12 volts, the EHPS module drivers shall shut down and a key cycle will be required to reset. The EHPS module shall withstand voltages up to a transient voltage of 58 volts for 400 milliseconds. If the supply voltage exceeds 55 volts, the EHPS module drives shall shut down and a key cycle will be required to reset. The 36 volts power supply is grounded directly to the negative terminal of the EHPS.
Conditions for Running the DTC
^ EHPS module in RUN mode.
^ Ignition switch in ACC or ON position.
^ Battery voltage between 12-58 volts.
Conditions for Setting the DTC
^ The EHPS module cannot validate the checksum from a programming event (software checksum error).
^ A replacement EHPS powerpack has been installed and not programmed.
Action Taken When the DTC Sets
^ The SERVICE BRAKE SYSTEM message and SERVICE STEER SYSTEM message will be displayed.
^ A chime will sound.
^ EHPS module operation is reduced and the electric motor control is inactive.
^ Stores DTC C0564 in the powertrain control module (PCM).
^ History DTC C0564 will be set in PCM.
Conditions for Clearing the DTC
^ After a successful programming event.
^ Using the scan tool.
^ A history DTC will clear after 255 consecutive ignition cycles if the condition for the malfunction is no longer present.
Diagnostic Aids
^ It may be necessary to perform the programming procedure more than once.
^ It may be necessary to check Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
Test Description
The number below refers to the step number on the diagnostic table.
2. This step checks to see if the problem has cleared after the EHPS control module has been reprogrammed.