Operation CHARM: Car repair manuals for everyone.

B153E




Liftgate Angle Sensor Malfunction - DTC B153E

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle Diagnostic System Check - Vehicle prior to using this diagnostic procedure.

* Review Strategy Based Diagnosis Strategy Based Diagnosis for an overview of the diagnostic approach.

* Diagnostic Procedure Instructions Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptor

DTC B153E 08

-
Power Liftgate Angle Sensor - External Signal Invalid

Circuit/System Description

The liftgate control module continuously monitors power liftgate operation and calculates its location and direction of travel using 2 inputs from the internal liftgate position sensor. One input returns the position of the liftgate relative to the latch along the x-axis and the other returns the position of the liftgate relative to the latch along the y-axis. The liftgate control module then uses these 2 inputs together to calculate its angle relative to the liftgate latch.

Conditions for Running the DTC

The system voltage is 9-16 V.

Conditions for Setting the DTC

The liftgate control module has detected an internal malfunction.

Action Taken When the DTC Sets

The power liftgate system will be disabled.

Conditions for Clearing the DTC

If the DTC is current, the liftgate control module must be replaced before the DTC can be cleared.

Diagnostic Aids

Note:
Before testing can be performed, the liftgate must be opened. Refer to Opening the Liftgate Without Electrical Power Service and Repair for the appropriate procedure.

Whenever the liftgate control module loses power or is disconnected, the ignition must be cycled OFF then ON in order to reactivate the liftgate control module.

Reference Information

Schematic Reference

Liftgate Schematics Liftgate Schematics

Connector End View Reference

Component Connector End Views Sunshade - Left Front

Description and Operation

Liftgate Description and Operation Liftgate

Electrical Information Reference

* Testing for Intermittent Conditions and Poor Connections Testing for Intermittent Conditions and Poor Connections

* Circuit Testing Circuit Testing

* Wiring Repairs Wiring Repairs

* Connector Repairs Connector Repairs

Scan Tool Reference

Control Module References Control Module References for scan tool information

Circuit/System Verification

Clear all DTCs and operate the power liftgate within the Conditions for Running the DTC. The DTC should not set.

If the DTC resets, replace the K39 liftgate control module.

Repair Instructions

Perform the Diagnostic Repair Verification Verification Tests after completing the diagnostic procedure.

Control Module References Control Module References for liftgate control module replacement, programming and setup