Operation CHARM: Car repair manuals for everyone.

Without Scan Tool

Self-Diagnosis Mode of Combination Meter

SELF-DIAGNOSIS FUNCTION
- Odo/trip meter segment, A/T indicator segment and ICC system display segment operation can be checked in self-diagnosis mode.
- Meters/gauges can be checked in self-diagnosis mode.

OPERATION PROCEDURE
1. Turn ignition switch ON, and switch the odo/trip meter to "trip A" or "trip B".

NOTE: If the diagnosis function is activated with the trip meter A displayed, the mileage on the trip meter A will indicate 0000.0, but the actual trip mileage will be retained. (Trip B operates the same way.)

2. Turn ignition switch OFF.




3. Turn ignition switch ON while pressing trip transfer switch and trip reset switch at the same time.
4. After ignition switch is turned ON, release trip transfer switch and trip reset switch. (With 7 seconds after the ignition switch is turned ON.)




5. All the segments on the odo/trip meter, A/T indicator and ICC system display illuminates, and simultaneously the low-fuel warning lamp indicator illuminates. At this time, the unified meter control unit is turned to diagnosis mode.

NOTE: If any of the segments is not displayed, replace combination meter.




6. Push the odo/trip meter switch. Each meter/gauge should indicate as shown in the figure while pushing odo/trip meter switch. (At this time, the low-fuel warning lamp goes off.)