P0132
DTC P0132 HO2S1Component Description
The heated oxygen sensor 1 is placed into the exhaust manifold. It detects the amount of oxygen in the exhaust gas compared to the outside air. The heated oxygen sensor 1 has a closed-end tube made of ceramic zirconia. The zirconia generates voltage from approximately 1 V in richer conditions to 0 V in leaner conditions. The heated oxygen sensor 1 signal is sent to the ECM. The ECM adjusts the injection pulse duration to achieve the ideal air-fuel ratio. The ideal air-fuel ratio occurs near the radical change from 1 to 0 V.
CONSULT-II Reference Value in Data Monitor Mode
On Board Diagnosis Logic
To judge the malfunction, the diagnosis checks that the heated oxygen sensor 1 output is not inordinately high.
DTC Confirmation Procedure
NOTE: If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at least 10 seconds before conducting the next test.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Select "DATA MONITOR" mode with CONSULT-II.
5. Restart engine and let it idle for 2 minutes.
6. If 1st trip DTC is detected, go to "Diagnostic Procedure".
WITH GST
Follow the procedure "WITH CONSULT-II" above.
EC-O2S1B1-01:
EC-O2S1B2-01:
Wiring Diagram
Diagnostic Procedure (Steps 1 - 2):
Diagnostic Procedure (Steps 3 - 4):
Diagnostic Procedure (Steps 5 - 7):
Diagnostic Procedure
Component Inspection
HEATED OXYGEN SENSOR 1
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select "MANU TRIG" and adjust "TRIGGER POINT" to 100% in "DATA MONITOR" mode with CONSULT-II.
3. Select "HO2S1 (B1)/(B2)" and "HO2S1 MNTR (B1)/(B2)".
4. Hold engine speed at 2,000 rpm under no load during the following steps.
5. Touch "RECORD" on CONSULT-II screen.
6. Check the following.
- "HO2S1 MNTR (B1)/(B2)" in "DATA MONITOR" mode changes from "RICH" to "LEAN" to "RICH" more than 5 times in 10 seconds. 5 times (cycles) are counted as shown in the figure given.
- "HO2S1 (B1)/(B2)" voltage goes above 0.6 V at least once.
- "HO2S1 (B1)/(B2)" voltage goes below 0.3 V at least once.
- "HO2S1 (B1)/(B2)" voltage never exceeds 1.0 V.
CAUTION:
- Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes between ECM terminal 16 [HO2S1 (B1) signal] or 35 [HO2S1 (B2) signal] and ground.
3. Check the following with engine speed held at 2,000 rpm constant under no load.
- The voltage fluctuates between 0 to 0.3 V and 0.6 to 1.0 V more than 5 times within 10 seconds.
- The maximum voltage is over 0.6 V at least 1 time.
- The minimum voltage is below 0.3 V at least 1 time.
- The voltage never exceeds 1.0 V.
1 time: 0 - 0.3 V -> 0.6 - 1.0 V -> 0 - 0.3 V
2 times: 0 - 0.3 V -> 0.6 - 1.0 V -> 0 - 0.3 V -> 0.6 - 1.0 V -> 0 - 0.3 V
CAUTION:
- Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.