P0745
DTC P0745 LINE PRESSURE SOLENOID VALVEDescription
The line pressure solenoid valve regulates the oil pump discharge pressure to suit the driving condition in response to a signal sent from the TCM.
CONSULT-II Reference Value:
On Board Diagnosis Logic
^ This is an OBD-II self-diagnostic item.
^ Diagnostic trouble code "P0745 L/PRESS SOL/CIRC" with CONSULT-II or 4th judgement flicker without CONSULT-II is detected under the following conditions.
- When TCM detects an improper voltage drop when it tries to operate the solenoid valve.
- When TCM detects as irregular by comparing target value with monitor value.
Possible Cause
^ Harness or connectors
(Solenoid circuit is open or shorted.)
^ Line pressure solenoid valve
DTC Confirmation Procedure
NOTE: If "DTC Confirmation Procedure" has been previously performed, always turn ignition switch OFF and wait at least 10 seconds before performing the next test.
After the repair, perform the following procedure to confirm the malfunction is eliminated.
With CONSULT-II
1. Turn ignition switch ON.
2. Select "MAIN SIGNALS" in "DATA MONITOR" mode for "A/T" with CONSULT-II.
3. Touch "START".
4. Engine start and wait at least 5 seconds.
5. If DTC is detected, go to "AT-130, "Diagnostic Procedure".
With GST
Follow the procedure "WITH CONSULT-II".
Diagnostic Procedure
1. CHECK INPUT SIGNAL
With CONSULT-II
1. Turn ignition switch ON.
2. Select "MAIN SIGNALS" in "DATA MONITOR" mode for "A/T" with CONSULT-II.
3. Start engine.
4. Read out the value of "LINE PRES SOL" while driving.
OK or NG
OK >> GO TO 4.
NG >> GO TO 2.
2. CHECK TCM POWER SUPPLY AND GROUND CIRCUIT
Check TCM power supply and ground circuit. Refer to AT-179, "MAIN POWER SUPPLY AND GROUND CIRCUIT".
OK or NG
OK >> GO TO 3.
NG >> Repair or replace damaged parts.
3. DETECT MALFUNCTIONING ITEM
Check A/T assembly harness connector pin terminals for damage or loose connection with harness connector.
OK or NG
OK >> Replace the control valve with TCM.
NG >> Repair or replace damaged parts.
4. CHECK DTC
Perform AT-129, "DTC Confirmation Procedure".
OK or NG
OK >> INSPECTION END
NG >> GO TO 2.